Jersey Concept Flooring & Renovation
Subfloor Leveling & Moisture Mitigation

Subfloor Leveling & Moisture Mitigation in NJ

ASTM F2170 moisture testing and self-leveling underlayment before a single plank goes down.

We run ASTM F2170 moisture testing and slab prep, documented before install starts, so the floor goes down on a slab within the manufacturer's limits.

Priced per project after moisture testingTypical range
Subfloor Leveling & Moisture Mitigation by Jersey Concept Flooring

About This Service

Flooring and adhesive manufacturers specify the moisture test and the limits their products need, and the National Wood Flooring Association's installation guidelines say testing to that specification is the only way to identify whether a slab's moisture level is adequate, and that documenting the result is part of meeting the flooring manufacturer's warranty requirements. We run ASTM F2170 relative humidity (RH) probe testing as standard on commercial slab installs, with calcium chloride testing available where a spec calls for it specifically.

When a slab reads outside the flooring manufacturer's tolerance, we install a moisture mitigation system or self-leveling underlayment rated for the reading — not a guess at "should be fine." Every test comes with written results for your files, your architect, or your flooring manufacturer's warranty documentation.

What's Included

  • ASTM F2170 relative humidity (RH) probe testing
  • Calcium chloride test option where specified
  • Self-leveling underlayment for out-of-flat or uneven slabs
  • Moisture mitigation system installation for out-of-tolerance readings
  • Written test results and documentation for your files
  • Pre-bid consultation on which flooring products your slab can accept
Request a Bid Need our COI or W-9 first? See insurance & licensing →
FAQ

Subfloor Leveling & Moisture Mitigation Questions, Answered

ASTM F2170 relative humidity testing measures the relative humidity inside a concrete slab rather than at its surface, and the NWFA installation guidelines say it predicts the equalized humidity through the slab once flooring covers it. Test with the method your flooring and adhesive manufacturers specify, and follow their limits.

It depends on the reading: a moderate excess usually calls for a moisture mitigation coating or system rated for that level; a severe reading may need additional slab drying time or a different flooring product. We'll present the real options rather than install over a reading that will void your warranty.

Yes — every test comes with written, dated results, which is exactly what an architect, GC or flooring manufacturer will ask for before signing off on the install.

Commercial & Trade

Send us the scope for subfloor leveling & moisture mitigation

Drawings, a finish schedule, square footage — or just photos and a deadline. We'll come back with a real number and a real date.

Call Text Free Quote